SERIES S14C THREADED

DOUBLE WINDOW SIGHT FLOW INDICATOR - 150LB ASME WITH INDEPENDENTLY-BOLTED GLASS RETAINERS

Indication Types:

  • Plain – No indicator for unobstructed view of media flowing in any direction
  • Rotator – Paddlewheel indicator used for clear media to enhance flow indication in any direction
  • Flapper – Side flapper to indicate horizontal flows in one direction for fast moving liquids
  • Drip Tube – For vertical downward flows at low flowrates

Standard Connections:

  • 1/2″ to 2″ NPT (Female)

Standard Ratings:

ASME CLASS 150
Material100°F200°F250°F300°F400°F500°F
Carbon Steel285 PSIG260 PSIG245 PSIG---
Bronze225 PSIG210 PSIG195 PSIG---
Stainless Steel275 PSIG235 PSIG225 PSIG215 PSIG195 PSIG170 PSIG

Note: Ratings are limited by standard glass and gasket types. For higher ratings, refer to drawings or consult our Sales Dept.

Standard Wetted Materials:

  • Body: Carbon Steel or 316SS
  • Gaskets: Neoprene (for CS Bodies), Gylon®3504 (for SS Bodies)
  • Indicator: 316SS Flapper, Teflon® Rotor, or 316SS Drip Tube
  • Rotator/Flapper Pin: 316SS
  • Glass: Tempered Borosilicate

Standard Non-Wetted Materials:

  • Glass Retainers: Carbon Steel (for CS Bodies) or Stainless Steel (for SS Bodies)
  • Fasteners: Plated Carbon Steel
  • Nameplate: SS

Options:

  • Up to 500°F and Higher Ratings
  • Buna-N, Fluorocarbon (Viton®), Ethylene Propylene, Gylon®3545, Graphite, Garlock® IFG-5500, and Silicone Gaskets
  • Gaseous Indicators
  • Exotic Body Materials (See Matrix)
  • Various Lens Materials (See Matrix)
  • SS Glass Retainers & Fasteners (See Matrix)
  • Glass Shields for Steam and Caustic Applications (See Matrix)
  • Socket Weld Connections
  • Butt Weld Connections (specify schedule and length)
  • C of C, MTR, NACE Certifications when requested at time of quotation
  • Offshore Coating
  • Custom Painting

Application Notes:

  • Saturated Steam Service: Upgraded gaskets and mica shields are recommended for saturated steam service. All ratings stated on our website and in our literature are non-steam ratings unless specified otherwise. Always contact our sales office for saturated steam ratings when needed.
  • Vacuum Service: Acceptable when using with elastomer seals
  • Gaseous Service: Not designed for lightweight gases
  • Corrosion: Before ordering, verify all materials of our sight flow indicators are compatible with the service media(s), intermittently used cleaners, the environment, and cleaning processes in conjunction with the temperatures and pressures of the application(s) and future applications. John C. Ernst Co. does not make chemical compatibility recommendations. Compatibility is the responsibility of the user.

Replacement Parts:

  • Please contact our sales department

Alternate Equipment: